›› 2020, Vol. 40 ›› Issue (3): 285-288.
• 综述 • 上一篇
邵琴,杨国利
收稿日期:
2019-01-25
修回日期:
2019-03-25
出版日期:
2020-03-28
发布日期:
2020-03-31
通讯作者:
杨国利
E-mail:guo_li1977@aliyun.com
1,
Received:
2019-01-25
Revised:
2019-03-25
Online:
2020-03-28
Published:
2020-03-31
摘要: 随着口腔锥形束CT(Cone beam Computer Tomography,CBCT)的应用,计算机辅助设计和计算机辅助制造(Computer Aided Design/ Computer Aided Manufacturing, CAD/CAM)以及3D打印技术的发展,数字化种植导板的应用逐渐增多,它能够控制种植体的精准植入、降低手术并发症。根据手术中的导航方式可分为部分导航和全程导航的数字化导板,本文就这两者的精确性、并发症、成本效益等的对比分析做一综述。
中图分类号:
邵琴 杨国利. 两种数字化导板的对比分析[J]. 口腔医学, 2020, 40(3): 285-288.
[1] | Buser D, Halbritter S, Hart C, Bornstein MM, Grutter L, Chappuis V, et al. Early implant placement with simultaneous guided bone regeneration following single-tooth extraction in the esthetic zone: 12-month results of a prospective study with 20 consecutive patients[J]. J Periodontol, 2009,80(1):152-62. |
[2] | Buser D, Bornstein MM, Weber HP, Grutter L, Schmid B, Belser UC. Early implant placement with simultaneous guided bone regeneration following single-tooth extraction in the esthetic zone: a cross-sectional, retrospective study in 45 subjects with a 2- to 4-year follow-up[J]. J Periodontol, 2008,79(9):1773-81. |
[3] | Linkevicius T, Puisys A, Vindasiute E, Linkeviciene L, Apse P. Does residual cement around implant-supported restorations cause peri-implant disease? A retrospective case analysis[J]. Clinical oral implants research, 2013,24(11):1179-84. |
[4] | Staubli N, Walter C, Schmidt JC, Weiger R, Zitzmann NU. Excess cement and the risk of peri-implant disease - a systematic review[J]. Clinical oral implants research, 2017,28(10):1278-90. |
[5] | Hermann JS, Schoolfield JD, Schenk RK, Buser D, Cochran DL. Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible[J]. J Periodontol, 2001,72(10):1372-83. |
[6] | Apostolakis D, Kourakis G. CAD/CAM implant surgical guides: maximum errors in implant positioning attributable to the properties of the metal sleeve/osteotomy drill combination[J]. International journal of implant dentistry, 2018,4(1):34. |
[7] | Ma B, Park T, Chun I, Yun K. The accuracy of a 3D printing surgical guide determined by CBCT and model analysis[J]. The journal of advanced prosthodontics, 2018,10(4):279-85. |
[8] | Hultin M, Svensson KG, Trulsson M. Clinical advantages of computer-guided implant placement: a systematic review[J]. Clinical oral implants research, 2012,23 Suppl 6:124-35. |
[9] | Chen CK, Yuh DY, Huang RY, Fu E, Tsai CF, Chiang CY. Accuracy of Implant Placement with a Navigation System, a Laboratory Guide, and Freehand Drilling[J]. The International journal of oral & maxillofacial implants, 2018,33(6):1213-8. |
[10] | Turbush SK, Turkyilmaz I. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study[J]. J Prosthet Dent, 2012,108(3):181-8. |
[11] | Geng W, Liu C, Su Y, Li J, Zhou Y. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement[J]. International journal of clinical and experimental medicine, 2015,8(6):8442-9. |
[12] | D'Haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computer-guided implant surgery[J]. Periodontology 2000, 2017,73(1):121-33. |
[13] | Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review[J]. The International journal of oral & maxillofacial implants, 2014,29 Suppl:25-42. |
[14] | Torabi K, Farjood E, Hamedani S. Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature[J]. Journal of dentistry (Shiraz, Iran), 2015,16(1):1-9. |
[15] | Pattanaik S, Pattanaik BK. Fabrication of a surgical guide with help of a milling machine by ridge mapping method[J]. Journal of Indian Prosthodontic Society, 2013,13(1):61-5. |
[16] | Scherer U, Stoetzer M, Ruecker M, Gellrich NC, von See C. Template-guided vs. non-guided drilling in site preparation of dental implants[J]. Clinical oral investigations, 2015,19(6):1339-46. |
[17] | Naziri E, Schramm A, Wilde F. Accuracy of computer-assisted implant placement with insertion templates[J]. GMS Interdisciplinary plastic and reconstructive surgery DGPW, 2016,5:Doc15. |
[18] | Chang RJ, Chen HL, Huang LG, Wong YK. Accuracy of implant placement with a computer-aided fabricated surgical template with guided parallel pins: A pilot study[J]. Journal of the Chinese Medical Association : JCMA, 2018,81(11):970-6. |
[19] | Fang Y, An X, Jeong SM, Choi BH. Accuracy of computer-guided implant placement in anterior regions[J]. J Prosthet Dent, 2018. |
[20] | Bencharit S, Staffen A, Yeung M, Whitley D, 3rd, Laskin DM, Deeb GR. In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery[J]. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 2018,76(7):1431-9. |
[21] | Boverramos F, Vi?aalmunia DJ, Cerveraballester PJ, Pe?arrochadiago DM, PhD, Garcíamira MB, et al. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies[J]. Int J Oral Max Impl, 2017,33(1):101-15. |
[22] | Marliere DAA, Demetrio MS, Picinini LS, De Oliveira RG, Chaves Netto HDM. Accuracy of computer-guided surgery for dental implant placement in fully edentulous patients: A systematic review[J]. European journal of dentistry, 2018,12(1):153-60. |
[23] | Kuhl S, Zurcher S, Mahid T, Muller-Gerbl M, Filippi A, Cattin P. Accuracy of full guided vs. half-guided implant surgery[J]. Clinical oral implants research, 2013,24(7):763-9. |
[24] | Choi W, Nguyen BC, Doan A, Girod S, Gaudilliere B, Gaudilliere D. Freehand Versus Guided Surgery: Factors Influencing Accuracy of Dental Implant Placement[J]. Implant Dent, 2017,26(4). |
[25] | Zhou W, Liu Z, Song L, Kuo CL, Shafer DM. Clinical Factors Affecting the Accuracy of Guided Implant Surgery-A Systematic Review and Meta-analysis[J]. The journal of evidence-based dental practice, 2018,18(1):28-40. |
[26] | A Ferhat M, Mahmut S, Murat Y, Erol E. Effect of surgical drill guide on heat generated from implant drilling[J]. Journal of Oral & Maxillofacial Surgery Official Journal of the American Association of Oral & Maxillofacial Surgeons, 2009,67(12):2663-8. |
[27] | Benington IC, Biagioni PA, Briggs J, Sheridan S, Lamey PJ. Thermal changes observed at implant sites during internal and external irrigation[J]. Clinical oral implants research, 2010,13(3):293-7. |
[28] | A. RE, D. D. S, T. Albrektsson, Ph. D. Temperature threshold levels for heat-induced bone tissue injury: A vital-microscopic study in the rabbit[J]. J Prosthet Dent, 1983,50(1):101-7. |
[29] | Tehemar SH. Factors affecting heat generation during implant site preparation: a review of biologic observations and future considerations[J]. The International journal of oral & maxillofacial implants, 1999,14(1):127-36. |
[30] | Eriksson RA, Albrektsson T, . The effect of heat on bone regeneration: an experimental study in the rabbit using the bone growth chamber[J]. Journal of Oral & Maxillofacial Surgery Official Journal of the American Association of Oral & Maxillofacial Surgeons, 1984,42(11):705-11. |
[31] | dos Santos PL, Queiroz TP, Margonar R, Ac DSC, Jr BW, Rezende RR, et al. Evaluation of bone heating, drill deformation, and drill roughness after implant osteotomy: guided surgery and classic drilling procedure[J]. Int J Oral Max Impl, 2014,29(1):51. |
[32] | Younes F, Eghbali A, De Bruyckere T, Cleymaet R, Cosyn J. A randomized controlled trial on the efficiency of free-handed, pilot-drill guided and fully guided implant surgery in partially edentulous patients[J]. Clinical oral implants research, 2018. |
[33] | Shen P, Zhao J, Fan L, Qiu H, Xu W, Wang Y, et al. Accuracy evaluation of computer-designed surgical guide template in oral implantology[J]. Journal of Cranio-Maxillo-Facial Surgery, 2015,43(10):2189-94. |
[34] | Sethi A, Kaus T. Immediate Replacement of Single Teeth With Immediately Loaded Implants: Retrospective Analysis of a Clinical Case Series[J]. Implant Dent, 2016,26(1):30. |
[35] | Van dVT, Glor F, De BH. A model study on flapless implant placement by clinicians with a different experience level in implant surgery[J]. Clinical oral implants research, 2010,19(1):66-72. |
[1] | 吴迪 汤春波. 穿颧种植用于修复上颌后部骨量不足的研究进展[J]. , 2020, 40(7): 639-643. |
[2] | 汪汉池 孟繁荣 方蛟 秦勤 辛禧瑞 周延民. 美学区即刻种植联合钛网引导组织再生1例[J]. , 2020, 40(2): 146-150. |
[3] | 邹英楠 史久慧. 动态载荷下双种植体单冠修复下颌磨牙的三维有限元分析[J]. , 2019, 39(12): 1078-1081. |
[4] | 徐双波 姚 红 许小会. 不同冠根比短种植体在上颌后牙区种植修复的短期临床研究[J]. , 2019, 39(12): 1090-1094. |
[5] | 潘文辉 汤春波. 下颌前牙区种植修复的临床应用研究[J]. , 2019, 39(10): 924-927. |
[6] | 王茂夏 向琳. 重度牙周炎患者的全口种植时机考量[J]. , 2019, 39(10): 941-943. |
[7] | 林彦君. 重度牙周炎患者种植修复时机的考量[J]. , 2019, 39(10): 944-947. |
[8] | 王洋 王柏翔 杨国利. 角化粘膜宽度对后牙区种植体健康的影响[J]. , 2019, 39(9): 823-826. |
[9] | 刘瑞敏 陈江 周勇 罗谷声 苏恩典 吴东. 后牙区角化黏膜宽度小于2mm时,角化黏膜移植是必要的吗?[J]. , 2019, 39(9): 827-830. |
[10] | 赵丽娜 刘鑫 唐旭炎. 上颌前牙单牙即刻种植术后即刻修复和延期修复的临床效果比较[J]. , 2019, 39(9): 799-804. |
[11] | 申林 兰小琴 汪婷婷 张红. 骨转换标志物对于牙槽嵴重度吸收患者咀嚼效能与两种改良牙合型全口义齿戴用的影响[J]. , 2019, 39(9): 811-814. |
[12] | 陈娅倩 杨醒眉. 上颌后牙区游离端连续缺失且垂直骨量不足3 mm时种植治疗选择考量[J]. , 2019, 39(8): 731-734. |
[13] | 徐丽娜 邱憬. 高脂血症对钛种植体骨结合影响的研究进展[J]. , 2019, 39(6): 557-560. |
[14] | 黄若萱 黄宝鑫 武诗语 陈建宇 于晓琳 李志鹏. 口内数字化印模技术在口腔种植中的应用现状与研究进展[J]. , 2019, 39(6): 539-543. |
[15] | 苏恩典. 数字化印模在口腔种植中的应用现状[J]. , 2019, 39(6): 544-546. |
阅读次数 | ||||||
全文 |
|
|||||
摘要 |
|
|||||