›› 2021, Vol. 41 ›› Issue (12): 1111-1116.

• 临床研究 • 上一篇    下一篇

数字印模技术在下颌游离端可摘局部义齿制作中的应用

张力1,姚丽娜1,林滔2   

  1. 1. 河北省邯郸市口腔医院
    2. 珠海市三通陶瓷有限公司
  • 收稿日期:2021-05-21 修回日期:2021-08-04 出版日期:2021-12-28 发布日期:2021-12-31
  • 通讯作者: 张力 E-mail:13313202076@163.com
  • 基金资助:
    河北省卫生厅科技成果推广课题

Application of digital impression technology in the fabrication of free end removable partial denture of mandible

  • Received:2021-05-21 Revised:2021-08-04 Online:2021-12-28 Published:2021-12-31

摘要: [摘要] 目的 探讨使用模拟压力数字模型进行游离端可摘局部义齿制作技术的应用。方法 对21个研究对象采用2种不同方法制作义齿。实验组使用3shape口腔数字印模仪扫描患者口腔软硬组织形态及咬合关系,生成数字模型,与患者CBCT数据一同导入义齿设计软件。依据余留牙位置将CBCT影像与数字模型进行拟合对齐,获得骨形态与对应粘膜厚度信息。对数字模型进行虚拟磨除或缓冲操作,生成模拟压力数字模型,在此模型上设计义齿支架,3D打印支架,最后排牙充胶完成义齿制作。对照组采用模型置换技术获得压力印模模型完成义齿制作。通过测试对比两组义齿临床效果,并对两种方式取得的工作模型游离端上对应的63个位点粘膜形态差异进行测量分析。结果21个研究对象,实验组粘膜压痛比例4.76%明显低于对照组23.81%。模拟压力数字模型与压力印模模型对应的63个位点粘膜差异性分析显示,近基牙端牙槽嵴顶软组织变形,实验组与对照组没有显著性差异,P=0.11;远基牙端实验组软组织形变显著大于对照组,P<0.05;下颌隆突区实验组比对照组有更多缓冲空间,形态存在显著性差异,P<0.05。结论 将数字化印模与CBCT数据拟合进行个性化数字模型修整,可以选择性调整粘膜压力分布,有效缓解游离端可摘局部义齿游离端不均匀下沉及压痛,临床效果满意。

关键词: 数字印模, CBCT, 游离端可摘局部义齿

Abstract: [Abstract] Objective To investigate the application of digital analog pressure model in the fabrication of free end removable partial dentures. Methods Two different methods were used to make dentures for 21 subjects . In the experimental group, the soft and hard oral tissue morphology and occlusal relationship of the patients were scanned with 3SHAPE oral digital impression instrument, and the digital model was generated, which was imported into the denture design software together with the CBCT data of the patients. CBCT images and digital model images were fitted and aligned according to the position of remaining teeth to obtain the information of bone morphology and corresponding mucosal thickness. Virtual grinding or buffering operation was carried out on the digital model to generate the analog pressure digital model on which the dental prosthesis framework was designed.the framework was 3D printed and the prosthesis was completed through tooth arrangement and glue filling. In the control group, pressure impression model was obtained by model replacement technique to complete the denture fabrication. The clinical effect of two groups of dentures was compared by testing. The morphological differences of mucosa at 63 sites on the free end of the working model obtained by the two methods were measured and analyzed. Results Among 21 subjects, the proportion of mucosal tenderness in the experimental group was 4.76% significantly lower than that in the control group, 23.81%. The mucosal differences of 63 sites between the simulated pressure digital model and the pressure impression model were analyzed. There was no significant difference between the experimental group and the control group in soft tissue deformation of alveolar crest near abutment(P=0.11); The soft tissue deformation of distal abutment teeth in the experimental group was significantly greater than that in the control group(P<0.05);In the mandibular protuberance area, the experimental group had more buffer space than the control group, and there was a significant difference in morphology(P<0.05). Conclusion The digital impression was fitted with CBCT data for personalized digital model modification, which can selectively adjust the mucosal pressure distribution and effectively relieve the uneven subsidence and tenderness of the free end of the removable partial denture. The clinical effect was satisfactory.

Key words: digital impression, CBCT, free end removable partial denture

中图分类号: