›› 2013, Vol. 33 ›› Issue (1): 40-43.

• 基础与临床研究 • 上一篇    下一篇

Vitallium 2000+钴铬钼合金和纯钛在不同人工唾液中耐腐蚀性的评价

周群,余和东,苗磊,郭蕾   

  1. 中国医科大学附属盛京医院
  • 收稿日期:2012-04-23 修回日期:2012-05-19 出版日期:2013-01-29 发布日期:2013-02-05
  • 通讯作者: 周群 E-mail:yuhedong@163.com

Evaluation on corrosion resistance of Vitallium 2000 plus co-cr-mo alloy and titanium in different artificial saliva

  • Received:2012-04-23 Revised:2012-05-19 Online:2013-01-29 Published:2013-02-05

摘要: [摘要] 目的 评价Vitallium 2000+钴铬钼合金和纯钛对不同氟浓度和溶解氧浓度的耐腐蚀性。方法 采用ZahnerIM6e型电化学工作站及THALESanalysis软件测得金属试件在不同人工唾液中的动电位极化曲线,并得到自腐蚀电位(Ecorr)、自腐蚀电流密度 (Icorr)和极化电阻(Rp)等指标。结果 在酸性、溶解氧浓度(DO)≥ 8.1 ppm的人工唾液中加入0.05% F-,纯钛试件极化曲线上移,Icorr增大,Rp减小(P﹤0.05),而Vitallium试件极化曲线没有偏移, Icorr、Rp基本不变(P﹥0.05);当F-浓度增大到0.2%,纯钛和Vitallium试件极化曲线均上移,Icorr增大,Rp减小(P﹤0.05)。当纯钛和Vitallium试件处于无氧状态(DO≤0.1 ppm),极化曲线均上移,Icorr增大,Rp减小(P﹤0.05)。结论 低浓度氟不会影响Vitallium 2000+钴铬钼合金的耐腐蚀性,但会降低纯钛的耐腐蚀性;高浓度氟和低溶解氧均会降低两者的耐腐蚀性。

关键词: 纯钛, Vitallium, 电化学腐蚀, 人工唾液, titanium , Vitallium , electrochemical corrosion , artificial saliva

Abstract: Abstract: Objective To evaluate the corrosion resistance of Vitallium 2000 plus Co-Cr-Mo alloy and pure titanium in artificial saliva with different fluoride and dissolved-oxygen concentrations. Methods ZahnerIM6e electrochemical workstation and THALES analysis software were applied to measure the polarization curves of the two metal specimens in different artificial saliva, and the Ecorr,Icorr and Rp were acquired. Results In 0.05% F-,DO≥8.1 ppm acidic artificial saliva, polarization curves of titanium specimen shifted, Icorr increased and Rp decreased (P < 0.05); however, polarization curves of Vitallium specimen didn't offset, while Icorr and Rp didn't change basically(P > 0.05). When the F- concentration was increased to 0.2% , the polarization curves of both titanium and Vitallium test pieces shifted, Icorr increased and Rp decreased (P < 0.05). When DO≤0.1 ppm ,the polarization curves of both titanium and Vitallium test pieces shifted, Icorr increased and Rp decreased (P < 0.05). Conclusion Low concentrations of fluorine will not affect the corrosion resistance of Vitallium 2000 plus Co-Cr-Mo alloy, but they can reduce the corrosion resistance of pure titanium. High concentrations of fluorine and low concentrations of oxygen will reduce the corrosion resistance of Vitallium 2000 plus Co-Cr-Mo alloy and titanium.

中图分类号: