摘要: 目的 研究固化厚度对光固化大块充填树脂的透明度及透光性的影响。方法 以大块充填树脂Tetric N-Ceram Bulk Fill和Filtek Bulk-fill Flowable为评价对象,以传统光固化复合树脂Filtek Z100和Filtek Z250为对照,每种树脂分别制备成不同厚度(1、2、3和4 mm)、直径4 mm的试件。使用牙科色度计测量试件的CIEL*a*b*参数,计算每种树脂不同厚度的透明度(TP)。测量每种树脂不同厚度下的光辐照度值(T)。采用单因素方差分析及均值间的Tukey's post-hoc LSD多重比较对各测试数据进行统计分析。结果 各品牌树脂的透明度及透光性均随厚度的增加而降低(PTP=0.000;PT=0.000);相同厚度下,Tetric N-Ceram Bulk Fill和Filtek Bulk-fill Flowable的透明度及透光性均较Filtek Z100和Filtek Z250有显著提高(1、2、3、4 mm,P=0.000)。结论 随厚度增加,Tetric N-Ceram Bulk Fill和Filtek Bulk-fill Flowable的透明度及透光性有所下降,但明显优于Filtek Z100和Filtek Z250。

关键词: 大块充填树脂, 厚度, 透明度, 透光性, 光固化

Abstract: Objective To evaluate the influence of thickness on the translucency parameters and light transmittance of Bulk-fill composites. Methods Two Bulk-fill composite (Tetric N-Ceram Bulk Fill and Filtek Bulk-fill Flowable) and two traditional light-cured resin composite (Filtek Z100) were tested in this study. Each composite with different thickness (1、2、3 and 4mm) were prepared (n= 5 per group) and then, the L*, a* and b* values of each sample were analyzed with a spectrophotometer, which was used to calculate the translucency parameter (TP) with different thickness on black and white background. Furthermore, the light transmittance (T) of each resin at different thickness was measured. The results of each test were analyzed with one-way ANOVA followed by Tukey's HSD test using SPSS 21.0 software package. Results For the four resins composites studied in this experiment, there is a trend of decreasing translucency parameter and light transmittance as the thickness increased. For the same thickness, the translucency parameters and light transmittance of Tetric N-ceram Bulk Fill and Filtek Bulk-fill Flowable were significantly higher than that of Filtek Z100 and Filtek Z250 (P<0.05). Conclusions The transparency parameter and light transmittance of Tetric N-ceram Bulk Fill and Filtek Bulk-fill Flowable decreased with increasing thickness, but were significantly higher than that of Filtek Z100 and Filtek Z250.

Key words: Bulk fill composite, thickness, translucency, light transmittance, light cure