›› 2020, Vol. 40 ›› Issue (9): 786-791.

• 基础研究 • 上一篇    下一篇

激光联合氟钾酚醛树脂对牙本质小管封闭作用的实验研究

王芳1,孙慧斌1,李泽雨2,孙莉青1   

  1. 1. 青岛大学附属医院口腔科
    2. 青岛大学口腔医学院
  • 收稿日期:2019-12-17 修回日期:2020-03-02 出版日期:2020-09-28 发布日期:2020-10-07
  • 通讯作者: 孙慧斌 E-mail:shb353.qindao@163.com

Experimental study on the effect of laser combined with potassium fluoride-formaldehyde resin on closing dentinal tubules

  • Received:2019-12-17 Revised:2020-03-02 Online:2020-09-28 Published:2020-10-07

摘要: 【摘要】目的:通过扫描电镜观察刷牙实验前后氟钾酚醛树脂脱敏剂(fluorine potassium phenolic resin desensitizer,FR)、激光、激光联合氟钾酚醛树脂脱敏剂对牙本质小管的封闭情况,探讨不同脱敏方法对牙本质小管的封闭效果及抗洗刷能力。为临床上激光联合氟钾酚醛树脂脱敏剂的应用提供实验依据和理论支持。方法:选择新鲜拔除的第三磨牙48颗,要求牙冠完整、无龋损,制备成3mm*3mm*2.5mm的牙本质模块,根据表面脱敏方法不同随机分为四组:A组对照组;B组为氟钾酚醛树脂脱敏剂组;C组激光组;D组为激光联合氟钾酚醛树脂脱敏剂组。B、C、D三组脱敏处理后,每组均随机选择6个标本作为即刻组 ,其余6个标本作为磨损组,进行刷牙实验 。每组随机选择一半标本沿牙本质方向纵行劈开,用于观察纵剖面。扫描电镜观察四组样本牙本质小管的表面封闭情况及纵剖面牙本质小管的封闭深度,所得的数据均在SPSS24.0软件上进行统计学分析。结果:1、B、C、D三组均能在牙本质表面形成有效封闭(P<0.05),D组具有更佳的封闭效果。2、纵剖面观察,B/D两组封闭深度差异无统计学意义(P>0.05),均深于C组(P<0.05)。3、刷牙磨耗试验后B/C/D三组牙本质小管口的封闭效果有统计学差异(P<0.05),两两比较,D组表面封闭性优于B、C两组(P<0.05),B组优于C组(P<0.05);4、纵剖面 封闭深度比较,B、 D两组均大于C组(P<0.05)。结论:1. 氟钾酚醛树脂脱敏剂、激光、激光和氟钾酚醛树脂脱敏剂联合应用均能在牙本质表面形成有效封闭。2. 激光和氟钾酚醛树脂脱敏剂联合应用对牙本质小管的封闭效果要优于单用脱敏剂或激光,更能耐受机械性刷洗,效果持久而稳定;激光封闭牙本质小管的深度较小,且抗机械性刷洗的能力较差。

关键词: 激光, 氟钾酚醛树脂脱敏剂, 牙本质过敏症, 扫描电镜, 牙本质小管

Abstract: 【 abstract 】 objective: The sealing effect of dentin tubule and anti-brushing ability of different desensitization methods were observed by scanning electron microscope.evaluateing zhe effect of potassium fluoride resin desensitizer, laser and laser combined with potassium fluoride phenolic resin desensitizer.So that providing experimental basis and theoretical support for the clinical application of laser combined with fluoropotassium phenolic resin desensitizer.Methods: 48 caries free third molars were selected and prepared into 3mm*3mm*2.5mm dentin blocks.They were randomly divided into four groups according to different desensitization methods.Group A :control group; Group B :potassium fluoride phenolic resin desensitizer group; Group C :laser group; Group D : laser combined with fluoropolyphenolic resin desensitizer group. In group B/C/D, 6 samples were randomly selected as immediate group and the remaining 6 samples were selected as wear group for the brushing experiment. Half of the dentin specimens were randomly selected to be split in each group to observe the longitudinal profile. The surface closure of the dentinal tubules of the blank group and the test group was observed by scanning electron microscope.The morphological analysis was performed about the representative areas to observe the closure depth of dentin tubules in longitudinal profile. Using SPSS 24.0 analyze all date .Results: 1. Group B, group C and group D could effectively block the dentin surface (p < 0.05). 2. In pairwise comparison, there was no statistical difference in the depth of closure between the b/d groups(p >0.05), however, both are deeper than group C(p <0.05).3. After brushing tooth, The differences among the three groups in sealing dentin tubule orifice were significant(p < 0.05). group D was better than groupB and group C, groupB was better than group c (p < 0.05).4. After brushing tooth ,as the depth of longitudinal section ,group B and group D were deeper than group C (p < 0.05). Conclusion:1.Fluorine potassium phenolic resin desensitizer ,laser and the combination of laser and fluorine potassium phenolic resin desensitizer can effective seal dentin surface.2.The effect of the combination of laser and potassium fluoropotassium phenolic resin desensitizing on sealing dentinal tubules is better and more durable than that of desensitizing agent or laser alone. The depth of laser-closed dentinal tubules is small, and the ability of mechanical brushing is poor.

Key words: laser, Potassium fluoride phenolic resin desensitizer, Dentin hypersensitivity, SEM, dentinal tubules