下颌不同骨质条件下All-on-4即刻负载的有限元分析

张莉, 顾卫平()   

  1. 南京医科大学附属口腔医院综合诊疗科, 口腔疾病研究与防治国家级重点实验室培育建设点(南京医科大学),江苏省口腔转化医学工程研究中心(南京医科大学), 江苏南京 (210029)
  • 收稿日期:2026-02-07 出版日期:2026-11-28 发布日期:2026-11-18
  • 通讯作者: 顾卫平 E-mail:willim90@163.com
  • 基金资助:
    江苏省科教能力提升工程——江苏省研究型医院(YJXYYJSDW4);江苏省医学创新中心(CXZX202227)

Finite element analysis of All-on-4 immediate loading under different mandibular bone conditions

ZHANG Li, GU Weiping()   

  1. Department of General Dentistry, The Affiliated Stomatological Hospital of Nanjing Medical University, State Key Laboratory Cultivation Base of Research, Prevention and Treatment for Oral Diseases(Nanjing Medical University), Jiangsu Province Engineering Research Center of Stomatological Translational Medicine(Nanjing Medical University), Nanjing 210029, China
  • Received:2026-02-07 Online:2026-11-28 Published:2026-11-18

摘要:

目的 探索下颌无牙颌不同骨质条件下All-on-4即刻负载时,符合生物力学原则的修复设计方案。方法 选择1例下颌骨严重萎缩的无牙颌患者的锥形束计算机断层扫描(cone-beam computed tomography,CBCT)数据,结合种植体、基台、支架、牙冠的参数,建立Ⅰ、Ⅱ、Ⅲ、Ⅳ类下颌骨的实体模型,每种模型分别设计钛和树脂两种支架材料,并应用3种加载方案模拟尖牙保护牙合(A)、组牙功能牙合不带悬臂(B)、组牙功能牙合带悬臂(C),按照咀嚼周期动态施加总载荷200 N,计算皮质骨的应力值、种植体的微动及支架的变形量,并进行数据分析。结果 同一支架材料及加载方案下比较不同骨质条件下种植体最大微动:Ⅰ类<Ⅱ类<Ⅲ类<Ⅳ类骨组;相同骨质及支架材料条件下,加载方案A方案的皮质骨von Mises应力峰值均小于B方案、C方案;动态载荷时,皮质骨的von Mises应力从第二阶段到第四阶段整体呈上升趋势,且最大值出现在加载方案为C时。比较支架的变形量,钛支架组显著低于树脂支架组。结论 ①Ⅰ~Ⅳ类骨中,骨质条件的减弱不利于种植体的稳定;②在下颌无牙颌种植固定修复行即刻负载时,尖牙保护牙合的咬合接触设计在生物力学方面表现优于组牙功能牙合不带悬臂及组牙功能牙合带悬臂;③不同设计方案中钛支架较树脂支架更有利于降低支架的变形量峰值;④一个咀嚼周期中,牙尖斜面受力时皮质骨应力更大。

关键词: 下颌无牙颌, 骨质, 即刻负载, 有限元分析, All-on-4

Abstract:

Objective To explore biomechanical prosthodontic designs for All-on-4 immediate loading scheme in mandibular edentulous jaws under different bone quality conditions. Methods Cone-beam computed tomography (CBCT) data were selected from an edentulous patient with severe mandibular atrophy. Based on parameters of the implant, abutment, framework, and crown, models of mandible corresponding to bone Types Ⅰ, Ⅱ, Ⅲ, and Ⅳ were established. For each model, frameworks were designed using both titanium and resin materials, and three loading schemes were applied: canine protected occlusion(A), group function occlusion without cantilever(B), and group function occlusion with cantilever(C). A total load of 200 N was dynamically applied over a masticatory cycle to calculate the stress of cortical bone, the micromotion of implant and the deformation of framework, followed by data analysis. Results Comparison of the peak micromotion of implant under the same framework material and loading scheme across different bone qualities showed a trend of Group Ⅰ<Group Ⅱ<Group Ⅲ<Group Ⅳ. Under the same bone type and framework material, the peak von Mises stress in cortical bone in Group A was lower than that in Group B and Group C. Under dynamic loading, the von Mises stress of cortical bone showed an overall upward trend from Stage Ⅱ to Ⅳ, and reached the maximum in scheme C. When comparing the deformation of framework, the titanium framework group was significantly lower than the resin framework group. Conclusion ①In Types Ⅰ-Ⅳ bone, the weakening of bone is detrimental to the stability of implant. ②In immediate-load fixed prostheses for edentulous mandible, canine protected occlusion demonstrated superior biomechanical performance compared to group function occlusion without cantilever and group function occlusion with cantilever. ③Among different design schemes, titanium frameworks are more conducive to reducing the peak deformation of the framework than resin frameworks. ④Increased cortical bone stress occurred during lateral force application on cuspal inclines within an occlusal cycle.

Key words: mandibular edentulous jaws, bone quality, immediate loading, finite element analysis, All-on-4