口腔医学 ›› 2023, Vol. 43 ›› Issue (6): 500-506.doi: 10.13591/j.cnki.kqyx.2023.06.004

• 基础研究 • 上一篇    下一篇

零旋入扭矩下植入种植体及Bio-Oss胶原对骨结合过程影响的动物模型研究

吴勤超1,刘东2,黄佳3,朱载瓯1,宋晓萌1,丁旭1(),吴煜农1()   

  1. 1 南京医科大学附属口腔医院口腔颌面外科,江苏南京(210029)
    2 安徽医科大学第一附属医院口腔科,安徽合肥(230000)
    3 南京医科大学附属无锡人民医院口腔科,江苏无锡(214000)
  • 修回日期:2023-02-27 出版日期:2023-06-28 发布日期:2023-07-06
  • 通讯作者: 丁 旭 E-mail:dingxu2018@aliyun.com;吴煜农 E-mail:yunongwu@aliyun.com
  • 基金资助:
    国家自然科学基金(81772887);江苏省医学创新团队(CXTD2017036);江苏省科教能力提升工程——江苏省研究型医院(YJXYYJSDW4);江苏省医学创新中心(CXZX202227)

An animal model study on the effects of implants and Bio-Oss collagen on the process of osseointegration under zero screwing torque

WU Qinchao1,LIU Dong2,HUANG Jia3,ZHU Zai'ou1,SONG Xiaomeng1,DING Xu1(),WU Yunong1()   

  1. Department of Oral and Maxillofacial Surgery,Nanjing Medical University Affiliated Hospital, Nanjing 230031, China
  • Revised:2023-02-27 Online:2023-06-28 Published:2023-07-06

摘要:

目的 研究零旋入扭矩(insertion torque,IT)下植入种植体及Bio-Oss骨胶原对骨结合过程的影响。方法 3只Beagle犬按照牙列式分为右上、左上、左下、右下四个象限,每个象限中各拔除第2、3、4前磨牙,拔除术后3个月,在每个象限每个位点随机植入对照组(35 N·cm)、实验组A(0 N·cm)、实验组B(0 N·cm+Bio-Oss胶原)三种植入方式下的同种规格种植体。分别于术后12、18、24周各处死1只实验犬,进行大体观察,同时采用共振频率分析(resonance frequency analysis,RFA)测量各组种植体稳定性系数(implant stability quotients,ISQ),拍摄显微CT,用CTAn软件测量总骨量(bone volume,BV)和总体积(total volume,TV),计算BV/TV值,对实验中获得的各种数据进行统计学分析。结果 ①本实验中总共失败6枚种植体,每组各失败2枚种植体,总体留存率为83%。通过对处死时的标本观察发现各组不同时间点的部分下颌种植体相较于初始的植入位置,种植体颈部水平位置存在明显下降;部分种植体出现边缘骨吸收(marginal bone loss,MBL),颈部暴露。②对照组ISQ值随时间延长而增加,在18周时最高,24周时有所下降;而实验组A的ISQ值随时间增加而减少,而在实验组B在18周时ISQ值明显下降,24周时明显上升。各组间在三个时间点的ISQ值差异均无统计学意义;实验组B在18周与24周间ISQ值具有统计学差异(P<0.05),其余各组各时间段间均差异无统计学意义(P>0.05)。③通过影像学观察到在12周时0 IT组已经有明显的骨质生成。各组的BV/TV间差异无统计学意义(P>0.05),不同时间段之间也无统计学差异。结论 无IT下植入种植体后期同样可以获得好的骨结合程度,而无扭矩植入下结合使用Bio-Oss骨胶原可以促进骨结合进程。

关键词: 初期稳定性, 旋入扭矩, ISQ值, 骨结合, 种植体

Abstract:

Objective To study the effects of implants implanted under zero IT and Bio-Oss collagen on the process of osseointegration. Methods Three Beagle dogs were divided into four quadrants: upper right, upper left, lower left and lower right according to the dentition. The 2nd, 3rd, and 4th premolars were extracted in each quadrant. Three months after the extraction, in each quadrant and each position, three implants of the same size under three kinds of implantation modes were randomly implanted: control group(35 N·cm), experimental group A(0 N·cm), and experimental group B(0 N·cm+Bio-Oss collagen). One experimental dog was sacrificed at 12 weeks, 18 weeks, and 24 weeks after the operation, respectively, and the general observation was carried out. At the same time, the Resonance Frequency Analysis(RFA) was used to measure the implant stability quotients(ISQ) of each group.Micro-CT was taken; bone volume(BV) and total volume(TV) were measured with CTAn software; BV/TV value was calculated, and statistical analysis on various data obtained in the experiment was performed. Results ① A total of 6 implants failed in this experiment. Two implants failed in each group and the overall survival rate was 83%. By observing the specimens at the time of execution, it was found that the horizontal position of some of the mandibular implants at different time points in each group were significantly decreased compared with the initial implantation position;some of the implants had marginal bone loss(MBL), and the neck was exposed. ② The ISQ value of the control group increased with time, which was the highest at 18 weeks, and decreased at 24 weeks, while the ISQ value of the experimental group A decreased with time. The ISQ value of the experimental group B decreased significantly at 18 weeks, and increased at 24 weeks. There was no significant difference in the ISQ values between the groups at three time points;the ISQ value of the experimental group B was statistically different between 18 weeks and 24 weeks(P<0.05), and there was no statistical difference between the other groups at each time period (P>0.05). ③ Obvious bone formation was observed in 0 IT group at 12 weeks by imaging. There was no significant statistical difference between the BV/TV of each group(P>0.05), and there was no significant statistical difference between different time periods. Conclusion Implants without IT can also achieve goodosseointegration degree and the use of Bio-Oss collagen under torqueless implantation can promote the process of osseointegration.

Key words: primary stability, insertion torque, implant stability quotient, osseointegration, implant

中图分类号: